Corrugated metal pipes (CMPs) have been used as culverts in North America since the 1950s.Today, corrosion of CMPs is a major problem that requires an urgent and efficient solution to retrofit thousands of corroded CMPs across the country.One potential solution click here gaining wide acceptance is to use a fit-in Glass Fiber Reinforced Polymer (GFRP) liner inside the old CMPs and to connect them using polymer grout.In this paper, a methodology to retrofit corrugated metal culvert using a fit-in GFRP profile liner was developed and implemented.First, material characterization of the GFRP material and the epoxy grout were carried out for proper design of the retrofit system.

Second, full-scale CMP-GFRP composite section was tested under three-point bending configuration to observe the retrofitted culvert behavior to failure.The new CMP-GFRP section develops full composite action and shows failure capacity of 75 kip with a deflection of 3.52 in at the end of the test.Post failure of the polymeric grout, GFRP pipe failure was observed at mid-span location starting on the tension side.A finite element model was developed to understand the behavior of the CMP-GFRP composite pipe and to allow for turbo air m3f72-3-n the efficient design of the proposed retrofitting system.